Apollo manual call point on a commercial pillar

Fire Alarm Systems

Design, installation and maintenance of addressable and conventional fire alarms for commercial and public-sector sites across London and the Home Counties.

Fire Alarm Capabilities

Design, installation, commissioning and maintenance of fire detection and alarm systems to BS 5839-1, from addressable and conventional panels through to networked, wireless and aspirating detection, with clear cause-and-effect records at handover.

High-visibility engineer commissioning plant control panels on a commercial site

Design, Installation and Commissioning

Survey-led design, installation and commissioning of fire detection and alarm systems for commercial and public-sector buildings across London and the Home Counties.

Kentec Taktis touchscreen fire control panel interface used for cause-and-effect testing

Cause-And-Effect Testing

Witnessed cause-and-effect testing of call points, detectors, sounders and interfaces against the fire strategy and agreed acceptance criteria.

Advanced addressable fire system devices: Axis sounder-beacon, AlarmCalm unit, detectors and interface modules

Addressable and Conventional Systems

Addressable and conventional fire alarm systems specified to the building, occupancy and fire risk assessment, including detectors, call points and sounders.

Advanced MxPro 5 networked fire alarm control panel mounted on a wall in a commercial cafe

Networked Fire Alarm Systems

Networked panels and loops for multi-building and multi-storey sites, with clear zoning so operators can locate and manage events quickly.

Apollo REACH Wireless system: loop interfaces, detectors, sounders, call point and survey kit case

Wireless and Wire-Free Systems

Wireless and wire-free fire alarm options where cabling is constrained, specified on survey and commissioned to the same handover standard as wired systems.

Aspirating smoke detector with sampling pipes in a data centre environment

Aspirating Air Sampling Detection

Aspirating (air sampling) detection for high-value, high-airflow or early-warning applications, designed into the fire alarm package where the risk requires it.

Zoned fire protection pipework and valves interfaced to building fire systems

BMS, Access and Smoke-Control Interfaces

Interfaces to BMS, access control, smoke control and other plant so doors, dampers and related systems follow the agreed fire cause-and-effect.

Engineer testing control gear with a multimeter during a maintenance visit

Maintenance and Emergency Call-Outs

Planned preventative maintenance, battery and device replacement, and emergency call-outs so fire alarm systems remain available after handover.

Engineers reviewing building drawings and handover documentation

Zone Charts and O&M Documentation

Zone charts, as-built drawings, commissioning certificates and O&M packs aligned with BS 5839-1 for approval, handover and ongoing audit.

Fire Alarm System Installer in London

Bespoke Fire Alarm Systems

Building on a heritage dating back to 1986, we work throughout London and the Home Counties to install fire protection systems that combine high-quality detection equipment with clear documentation and dependable aftercare.

Systems are designed and delivered to NSI Gold standards for fire, with commercial and public-sector work as our primary focus, addressable and conventional detection, networked and wireless options, aspirating systems, plant interfaces, and maintenance after handover.

By installing a fire alarm system which will give you an early warning of the outbreak of fire, an effective alarm can prevent a small incident becoming a total devastation.

Red manual call point on a commercial concrete wall

Do All Businesses Need a Fire Alarm System?

UK fire safety law requires suitable fire detection and warning arrangements for the premises, determined by a fire risk assessment, not by a one-size-fits-all rule that every business must have a full fire alarm panel. In simple terms: if a fire broke out, could it be detected quickly, and could people in the building be warned?

That does not mean every premises needs the same system. The questions below are general prompts only; a competent fire-safety person should confirm what your site requires before you rely on this guidance:

  • Are your premises small, single-storey or open-plan?
  • Do you have any high-risk substances on-site such as chemicals?
  • Are there any high-risk activities on-site, such as cooking?
  • Are there vulnerable people in the building (e.g. children, elderly, disabled)?
  • If a fire broke out on-site it would be easily spotted straight away?
  • Would shouting 'fire' be easily heard by all occupants of the building?

If your answer to one or more of these questions is “no”, a surveyed fire detection and warning system is often appropriate. The level of protection required is defined by a fire risk assessment (carried out by others). Once that assessment is in place, our free survey helps design and specify a system that meets those requirements for your building.

London Fire Brigade appliance attending an incident on a UK high street

Compliance, Certification & Handover

Fire alarm installations are delivered against recognised UK standards with clear records for approval, handover and audit. Typical deliverables include as-built drawings, zone charts, commissioning certificates and O&M manuals, aligned with BS 5839-1 for non-domestic buildings.

Typical Scope

Design, install & commission

  • Addressable and conventional fire alarm systems
  • Design, installation, commissioning and cause-and-effect testing
  • Networked and wireless / wire-free systems
  • Aspirating (air sampling) detection
  • Interfaces with BMS, access control and smoke control
  • Maintenance, emergency call-outs, zone charts and O&M packs

Standards Reference

Fire detection & BS 5839

  • BS 5839-1, Fire detection and fire alarm systems for buildings (non-domestic)

Where your project also needs disabled refuge, fire telephone & toilet alarms (BS 5839-9), PAVA voice alarm (BS 5839-8) or EVAC (BS 8629), we design and install those systems as part of the wider life-safety package.

BAFE Registered

BAFE (British Approvals for Fire Equipment) is the independent registration body for third-party certificated fire safety organisations. It is not itself a UKAS-accredited certification body, licensed UKAS-accredited certification bodies audit companies against BAFE schemes, and BAFE lists providers on its Fire Safety Register while that certification remains valid.

We are BAFE Registered for the fire safety services shown against our listing. Many clients and insurers expect BAFE registration from companies that install or maintain fire detection and alarm systems.

Verify our listing on the BAFE Fire Safety Register, Registered Organisation 301168.

BAFE Fire Safety Register (bafe.org.uk)

Commercial interior prepared for fire detection and alarm installation
BAFE Fire Safety Register

Fire Alarm & Detection Systems Equipment

We are proud to install fire alarm technology from the world's leading brands

Our Fire Alarm System Installations

Examples of fire alarm systems that we have installed for our customers:

Dimco Exhibition Building, Westfield Stratford, Exterior

Fire alarm installation · exhibition / retail

Dimco Exhibition Building, Westfield Stratford, Interior

Fire alarm installation · exhibition / retail

Hilton Doubletree Kingston, External

Hotel · Kingston

Hilton Doubletree Kingston, Restaurant

Hotel · Kingston

John Keats Primary School, Classroom

Rotherhithe, London

John Keats Primary School, Playground

Rotherhithe, London

The Mayfair Townhouse, Garden Suite

Luxury lifestyle hotel · Mayfair, London

The Mayfair Townhouse, London

Luxury lifestyle hotel · Mayfair, London

Oaklands House, London

Apartment blocks · London

Oaklands House, Distance View

Apartment blocks · London

Sancroft Building, Collage

Paternoster Square, City of London

Sancroft Building, Exterior

Paternoster Square, City of London

Sancroft Building, Interior

Paternoster Square, City of London

Sancroft Building, Restrooms

Paternoster Square, City of London

Scape Bloomsbury, Exterior

Student accommodation · Bloomsbury, London

Scape Bloomsbury, Lounge

Student accommodation · Bloomsbury, London

University of West London, Exterior

Higher education · West London

University of West London, Reception

Higher education · West London

Wembley French School, Exterior

International school · Wembley, London

Wembley French School, Interior

International school · Wembley, London

Frequently Asked Questions

Talk to us

Need a Fire Alarm System?

Contact us for a free survey and expert advice on fire detection and alarm design for your premises.