Shopping centre concourse with ceiling loudspeakers for public address and voice alarm

PAVA Systems

Public address and voice alarm (PAVA) systems designed, installed and maintained for clear emergency messaging and everyday announcements.

Capabilities

From amplifiers and loudspeakers through to fire alarm integration, cause-and-effect testing, commissioning and maintenance, we deliver PAVA systems that are intelligible, zoned and testable, with clear handover files for operators and maintainers.

Multi-level shopping atrium where zoned public-address evacuation messages apply by floor and area

Zoned Evacuation Messages

Zone-based emergency messaging aligned to your fire strategy, with prioritised announcements and local control where required.

Multi-storey fire escape stairs used for staged, floor-by-floor building evacuation

Phased Evacuation

Staged or phased building evacuation messaging so floors and areas can be instructed in sequence under the fire plan.

Red manual call point on a concrete wall interfaced to the fire and voice-alarm system

Fire Alarm Integration

Interfaces to the fire detection and alarm system so voice messages follow the agreed cause-and-effect logic.

Occupied commercial lounge and café where public address and background music share the voice-alarm system

Background Music & General Announcements

Where the design allows shared PAVA infrastructure, we coordinate non-emergency paging and background music with emergency priority override.

High-ceiling event hall with trusses and loudspeaker positions for public address coverage

Amplifiers and Loudspeakers

Selection, placement and commissioning of amplifiers and loudspeakers for audibility and speech intelligibility across occupied spaces.

Kentec Taktis touchscreen fire control panel interface used for cause-and-effect testing

Cause-And-Effect Testing

Witnessed testing of message triggers, priorities and fault behaviour against the fire strategy and interface schedules.

APX engineer in black polo demonstrating a fire alarm and security panel during commissioning and handover

Commissioning

Structured audio commissioning, configuration records and operator familiarisation at handover.

Engineer testing control gear with a multimeter

Maintenance

Planned maintenance, routine testing and reactive support so PAVA systems remain available and compliant in service.

PAVA (public address and voice alarm) systems are covered by BS 5839-8. We align design, installation, commissioning, audibility testing, cause-and-effect records and ongoing maintenance with that standard and with the fire engineering inputs for your project, including interfaces to disabled communication and building systems where applicable.

Standards & Handover

PAVA & BS 5839-8

  • BS 5839-8, Voice alarm systems, design, installation, commissioning and maintenance
  • Zoned and phased evacuation messaging to the fire strategy
  • Fire alarm integration and cause-and-effect testing
  • Amplifiers, loudspeakers and day-to-day public address functions where specified

Related life-safety scopes: EVAC (BS 8629), disabled refuge, fire telephone & toilet alarms, fire alarm systems.

Typical Deliverables

  • Audio testing reports and as-commissioned settings
  • Cause-and-effect / interface witness sheets
  • Commissioning documentation and operator handover
  • Maintenance options aligned with BS 5839-8 and manufacturer guidance

Completed Project

Example PAVA delivery in the City of London, the Sancroft Building at Paternoster Square.

Sancroft Building, City of London PA/VA

Paternoster Square, City of London

Public address / voice alarm (PAVA) installation

Sancroft Building, Interior Systems

Paternoster Square, City of London

Amplifiers, loudspeakers and life-safety voice messaging

Frequently Asked Questions

Talk to us

Planning A PAVA System?

Share your drawings and fire strategy. We can advise on zoning, phased evacuation, amplifiers, loudspeakers and BS 5839-8 commissioning for a compliant PAVA installation.